Configuration via Serial Mode or Telnet Port


MatchPort b/g™ User Guide

54

Remote IP Address

This is the destination IP address used with an outgoing connection.

Remote IP Address : ( 0) ( 0) ( 0) ( 0)_

Note:

This option is not displayed when Hostlist is enabled from the

ConnectMode prompt (see page 47 for more information).

Remote Port

Set the remote TCP port number for the unit to make outgoing connections. This
parameter defines the port number on the target host to which a connection is
attempted.

Remote Port ( 0) ? _

To connect an ASCII terminal to a host using the unit for login purposes, use the
remote port number 23 (Internet standard port number for Telnet services).

Note:

This option does not display when Hostlist is enabled from the

ConnectMode prompt (see page 47 for more information).

DisConnMode

Disconnect Mode (DisConnMode) determines the conditions under which the unit will
cause a network connection to terminate. The current value displays in parentheses.

DisConnMode ( 0) ? _

Note:

All bit positions in the table that are blank represent "don't care" bits for

that particular option, which can be set to either a 0 or a 1 value.

The following table displays the available input options:

Disconnect Mode Option

7

6

5 4 3 2 1 0

Disconnect when Modem Control In is not asserted

(6)

1

Ignore Modem Control In

0

Telnet Com Port Cntrl and terminal type setup

(1)

1

Channel (port) password

(2)

1

Hard disconnect

(3)

0

Disable hard disconnect

1

State LED off with connection

(4)

1

Disconnect with EOT (^D)

(5)

1

(1) The MatchPort sends the "Terminal Type" upon an outgoing connection.
(2) A password is required for a connection to the serial port from the network.
(3) The TCP connection closes even if the remote site does not acknowledge the disconnection.
(4) When there is a network connection to or from the serial port, the state LED turns off instead of blinking.
(5) When Ctrl+D or Hex 04 is detected, the connection is dropped. Both Telnet Com Port Cntrl and

Disconnect with EOT must be enabled for Disconnect with EOT to function properly. Ctrl+D is only
detected going from the serial port to the network.

(6) When Modem Control In transitions from a high state to a low state, the network connection to or from the

serial port drops.