9

Single Weigh Operating Instructions
1. Park the vehicle in as level a location as possible.
2. Raise the platform to enable the scale. If the level lamp does

not indicate that the unit is level lower the platform and move
the truck. Repeat steps 1 and 2.

3. Turn the power switch located on the instrument panel to the

ON position. The M2000 weigh indicator should power up.
The readout on the indicator should be positive. When the
system is ready to use the green LED on the front panel will
go dark.

Note: The M2000 will display



after 10

seconds if the vehicle is not level.

4. Insert your ticket into the TM290 ticket printer.

The delivery hose, chutes, conveyors, etc. must be in
the storage position before continuing.

5. When the reading on the M2000 has stabilized push

[START] once. The printer will print the current time and
date, and the starting gross and net weights.

6. The M2000 will go into NET mode automatically when the

start button is pushed. The display will show zero “

” with the

net light illuminated.

7. Connect the delivery hoses. Unload or load the amount as

desired. Then disconnect the hoses and place in the storage

position.
The delivery hose, chutes, conveyors, etc. must be in
the storage position before pushing the END button.