Single weigh operating instructions – Rice Lake TradeRoute HL Series - Low Profile Operators Manual for Models from 2011 and Older 127465 User Manual
Page 12
9
Single Weigh Operating Instructions
1. Park the vehicle in as level a location as possible.
2. Raise the platform to enable the scale. If the level lamp does
not indicate that the unit is level lower the platform and move
the truck. Repeat steps 1 and 2.
3. Turn the power switch located on the instrument panel to the
ON position. The M2000 weigh indicator should power up.
The readout on the indicator should be positive. When the
system is ready to use the green LED on the front panel will
go dark.
Note: The M2000 will display
after 10
seconds if the vehicle is not level.
4. Insert your ticket into the TM290 ticket printer.
The delivery hose, chutes, conveyors, etc. must be in
the storage position before continuing.
5. When the reading on the M2000 has stabilized push
[START] once. The printer will print the current time and
date, and the starting gross and net weights.
6. The M2000 will go into NET mode automatically when the
start button is pushed. The display will show zero “
” with the
net light illuminated.
7. Connect the delivery hoses. Unload or load the amount as
desired. Then disconnect the hoses and place in the storage
position.
The delivery hose, chutes, conveyors, etc. must be in
the storage position before pushing the END button.