6. Trouble Shooting

Symptom

Probable Cause

Action

The scale indicator
will not power up.

a) Blown in-line fuse

b) Truck voltage is

less than 11 volts.

a) Replace in-line fuse, Norac

part # 100494, the fuse
holder should be located near

the battery or inside the cab.

b) Repair faulty electrical system

on truck. The panel requires

at least 11 volts to operate
properly.

Indicator turns off

or resets in the
middle of a
transaction –OR-

End button will not
function but start
seems to work

properly.

a) Low voltage to

control panel.

a) Check other electrical

equipment that may be
operating (IE. Air
conditioning). The charging

system on the vehicle may not
be maintaining at least 11
volts.

The M2000 will not
come on

automatically with
the system power
switch- it will only

power up when the
ON button on the

M2000 panel is
pushed – AND- The
indicator turns on

and off erratically
even when the level
light is on solid.

a) The indicator must

be configured to

power up
automatically.

a) Contact your local dealer or

Rice Lake Weighing Systems.

Only a qualified technician can
perform this configuration.