27

Yearly

-

Do all required weekly services checking all components

of the system.

-

Park system on a slope greater then seven degrees and
raise the scale. (For example a steep approach.) Turn on
the indicator and check to see if it shuts off in 10 seconds.
If the indicator does not shut of you may have a faulty tilt
sensor, consult you local scale dealer. You must do this
test in all four directions, front low, rear low, right side
low and left side low.

-

Disassemble each load cell location. Check all bushings for

excessive wear and replace if necessary. Grease the ends
of the upper load cell pin and lower eyebolt when
reassembling.

Note: Use quality high-pressure grease.
Note: Avoid bending or twisting the load cell wires.

To perform service on any of the scale parts (i.e. load cell,
bushings), the linkage assembly must be disassembled. The
following procedure must be followed when disassembling any
linkage.

Disassembly Procedure

-

Tools required:

7/16” wrench or socket

¾” wrench or socket

¾” hex Allen key (ratchet preferred)

¼” roll pin punch

Hammer

Large flat head screwdriver

11/16” wrench (required for hydraulics only)

5/8” wrench (required for hydraulics only)