Manual operation with set point relay, Set point relay override – Rice Lake TradeRoute HL Series - Low Profile Operators Manual for Models from 2011 and Older 127465 User Manual

Page 22

Advertising
background image

19

Manual Operation with Set Point Relay
With the optional set point relay installed, the delivery system can
still be operated manually. To run manually, configure the Set
Point relay option for manual operation. Section “

Configuring Set

Point Operation

” explains how to put the system in manual set

point mode. If the delivery switch is used the delivery pump will
begin pumping when the delivery switch is switched “on”, and will
stop only when this switch is switched “off”. If the delivery switch
is not used the delivery pump will always be on. See schematic in
section “

Optional Set Point Relay

” or the installation manual

(42736) for details.

Set Point Relay Override
If the set point relay fails during operation and was installed
according to the installation manual you can bypass the relay to
continue delivering. To do this turn the manual override switch to
the “on” position. See schematic in section “

Optional Set Point

Relay

” for operation of the manual override switch.