35

Symptom

Probable Cause

Action

The printer is
printing

unrecognisable
characters

a) The printer DIP

switch setting are

incorrect

b) The power supply

on the truck is

excessively noisy.

a) Turn the printer over and

check that the small switches

are set as follows: 1 on, 2 off,
3 off, 4 off, 5 off, 6 off, 7 on,
8 on, 9 off, 10 off

b) Contact Rice Lake Weighing

Systems, an in-line power
filter may be necessary.

The printing on the
ticket is faint or
hard to read.

a) The printer’s ink

ribbon may need to
be replaced.

b) The printer head

may be damaged.

a) replace ribbon, Norac part #

82282-1

b) Requires service by a

qualified technician.

Cannot load the

system to full
capacity without
getting “



” on

the display

a) Dead load has been

added to the scale
since it was
calibrated

a) Contact your local scale dealer

Display reads



” or “



a) A load cell has

become
disconnected.

a) Inspect for damage and

consult you local scale
dealer.

IF YOU SUSPECT THERE IS A PROBLEM INSIDE THE

CONTROL PANEL THAT REQUIRES THE WEIGHTS AND
MEASURES SEAL TO BE BROKEN YOU MUST CONTACT
RICE LAKE WEIGHING SYSTEMS PRIOR TO BREAKING THE
SEAL, OR HAVE A QUALIFIED SCALE DEALER BREAK THE
SEAL.
BREAKING THE SEAL MAY VIOLATE THE WEIGHTS AND
MEASURES APPROVAL OF THE SCALE.