External control, Control-in port – 360 Systems TCR Multi-Track User Manual

Page 105

Advertising
background image

TCR Series User's Guide

Machine Setup 5-21

External Control

MENU | Machine Setup | External Control

The Setup External Control Menu provides setup functions that pertain to the TCR’s RS-422 and
GPI (General Purpose Interface) control ports. To reach the Setup External Control Menu, select
item 3 (EXTERNAL CONTROL) on the Setup Menu.

SETUP EXTERNAL CONTROL

0. >

CONTROL-IN PORT

:

SINGLE REMOTE

1.

RS-422 EMULATION

:

BVW-75 VTR

2.

RS-422 BALLISTICS

:

MAX. SPEED

3.

RS-422 TRACK ARMING

4.

GENERAL PURPOSE I/O

'ENTER' OR NUMBER SELECTS MENU ITEM

PRESS 'EXIT' TO EXIT MENU

Setup External Control Menu

The functions in the Setup External Control Menu are listed below.

0. Control-In Port

Selects the function of the control input port.

1. RS-422 Emulation

Selects the type of RS-422 (9-pin) emulation. Choose BVW-75, DVW-500, PCM-7040, or
TCR native.

2. RS-422 Ballistics

Selects the emulated ballistics. Choose Standard, Maximum Speed, or Minimum Speed
for compatibility.

3. RS-422 Track Arming

Assigns RS-422 channels to TCR tracks.

4. General Purpose I/O

Assigns GPI input and output ports.

Each external control function is explained in detail in the following sections.

Control-In Port

The Control-In Port function allows you to set up the TCR’s multi-machine control capability.

MENU | Machine Setup | External Control | Control-In Port

Note

On the Setup External Control Menu, please leave the CONTROL
IN function set to OFF.