Track input, Sample rate converter input – 360 Systems TCR Multi-Track User Manual

Page 96

Advertising
background image

5-12 Error! No text of specified style in document.

TCR Series User's Guide

Set Process Delays

Sets “pre-read” delays to compensate for external process delays.

Each Audio I/O function is explained in greater detail in the following sections.

Track Input

MENU | Machine Setup | Audio I/O | Track Input

The Track Input functions allow selection of which set of inputs is routed to the TCR’s internal
crossfader for actual use during recording and monitoring. The function applies to both TCR4 and
TCR8.

Use the following steps to set the track inputs:

1. On the Setup Audio I/O Menu, select the appropriate track pair. The current setting is

highlighted.

2. Select the desired track input:

ANALOG (Track pair): Analog Input connectors are used.

AES (Track pair): Digital Input connectors are used.

SAMPLE RATE CONVERTER INPUT: the TCR’s internal SRC (Sample Rate
Converter) input is used. Refer to the “Sample Rate Converter” section below for
details.

Sample Rate Converter Input

MENU | Machine Setup | Audio I/O | SRC Input

The Sample Rate Converter function selects which set of digital inputs is routed to the TCR’s
internal Sample Rate Converter. The Sample Rate Converter Input, in turn, can then be selected on
any of the track input selection functions on the Setup Audio I/O Menu, with the ability to choose a
direct or converted input.

Please note:

The Sample Rate Converter Input function applies to digital inputs only.

If an AES input is sample rate converted (by choosing the “converted” setting), the input does
not have to be synchronous. In this way, mixing inputs at various sample rates is allowed.
However, only one pair of AES inputs can be converted.

With both the “direct” and “converted” options, you can assign an AES pair to more than one
set of channels using the TCR’s internal router. For example, If AES 1-2 DIRECT is
selected and then SAMPLE RATE CONVERTER INPUT is selected on the Track Input
3-4
and Track Input 5-6 functions, AES 1-2 will be recorded on tracks 1 through 6.

Use the following steps to set the Sample Rate Converter input:

1. On the Setup Audio I/O Menu, select the SAMPLE RATE CONVERTER INPUT

function. The current setting is highlighted.

2. Select the desired SAMPLE RATE CONVERTER input choice:

AES 1-2 CONVERTED: Digital inputs 1-2 are routed to the sample rate converter.

AES 1-2 DIRECT: Digital inputs 1-2 are used direct, with no conversion.