Installation 3-3

Installing Hardware

The TCR can be installed in tabletop fashion, or in a standard 19" equipment rack. Whichever
method you choose, ensure that there is adequate room for cables and proper ventilation for the
chassis.

Please note the following important points:

Each TCR model includes a dedicated power supply that is pre-configured at the factory for
the proper line voltage. Please verify that the voltage, as checked above the AC connector,
matches your supply line voltage.

GND

115 V~
230 V~

50-60 Hz
2.5 A MAX

For rack mounting, the TCR chassis requires 7 inches of vertical rack space (4 RU).

Provide a sufficient service loop for all rear chassis power, audio, sync and communications
cables.

The TCR can be installed at any angle, per the requirements and space limitations of your
facility.

Four 10-32 threaded holes located on the bottom of the chassis may be used as alternate
mounting points. Fasteners should not enter the chassis more than 0.5 inches [12 mm].

Safety Cautions

Please note the following important cautions:

Connect the TCR only to a grounded 50/60 Hz AC outlet providing the
correct voltage (115 VAC or 230 VAC as delivered).

Do not remove or defeat the grounding pin on the AC Power Cord. A
serious shock hazard may result from failing to make connection to a
properly grounded electrical outlet. Use of the reference grounding
post is not a substitute for the safety ground conductor.

Do not use this product in rain, or in damp or wet environments.

If necessary, replace the power cord only with Underwriters Laboratories recognized cord of
the same ratings.

To provide optimum air flow and maximum chassis cooling, do not obstruct the side air
intakes or block the rear exhaust fan. Failure to provide proper ventilation may cause early
component failure and/or create a fire hazard and can void your warranty.