Cub Cadet RZT-S Zero Electric User Manual

Page 100

Advertising
background image

RZT-S Zero

96

To Start: Sit in seat

Starter disable

Won't start until condition
met.

0 volts at pin B3 and B4

Seat switch is not being
depressed, poor connec-
tion, faulty switch, dam-
aged harness

To Start: Push blade knob
down/off

Starter disable

Won't start until condition
met.

5 volts at pin B5 and B6

PTO switch is ON, defec-
tive switch or a short in the
harness

To Start: Remove foot from
drive pedal

Starter disable

Won't start until condition
met.

Throttle signal not at cali-
brated neutral voltage

Drive pedal is not in a neu-
tral position or the TPS is
out of calibration

To Start: Place foot on
brake pedal

Starter disable

Won't start until condition
met.

0 volts at pin B1

Brake pedal is not
depressed, poor connec-
tion, faulty switch, dam-
aged harness

To Start: Press and hold
start/stop button

Starter disable

Won't start until condition
met.

Waiting for operator to
press and hold start but-
ton

Sometimes this condition
will appear to be met (the
graphic on the screen
changes) but the tractor
does not start (contactor
doesn't close) - This could
be a faulty VCM or com-
munication issue on the
control panel

Blades off: Overload /
Raise deck, restart blades

Operator error

Disables Blades

The speed of one or both
deck motors has fallen
below 2400 RPM for more
than 1 second

The blade speed is to low
for current cutting condi-
tions, the deck has stalled
due too much grass mate-
rial being cut at once or a
mechanical binding of the
deck motor.

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes

Advertising