Cub Cadet RZT-S Zero Electric User Manual

Page 104

Advertising
background image

RZT-S Zero

10
0

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

128

POST static gating test

Controller failure

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

512

Instantaneous phase over
current

Motor pulling too much
current, short bursts

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

1024

Motor has reached at tem-

perature of 105

o

C

Motor over loaded, faulty

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

2048

Throttle voltage outside
range

N/A

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

4096

Instantaneous controller
over voltage

Batteries over charged,
usually from regen. brak-
ing

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

8192

Internal error

Controller failure

Stopped: Right hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

16384

POST dynamic gating test

Controller failure

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

32768

Instantaneous under volt-
age

Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts

Blades off: Left deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

1

Controller over voltage

Batteries over charged,
usually from regen. brak-
ing

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes