Cub Cadet RZT-S Zero Electric User Manual

Page 102

Advertising
background image

RZT-S Zero

98

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

32

Motor hall sensor fault

Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

64

Controller under voltage

Battery voltage too low,
poor connection, corrosion

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

128

POST static gating test

Controller failure

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

512

Instantaneous phase over
current

Motor pulling too much
current, short bursts

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

1024

Motor has reached at tem-

perature of 105

o

C

Motor over loaded, faulty

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

2048

Throttle voltage outside
range

N/A

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

4096

Instantaneous controller
over voltage

Batteries over charged,
usually from regen. brak-
ing

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

8192

Internal error

Controller failure

Stopped: Left hub fault /
Restart, if problem per-
sists contact service

Fault

Disables Blades and Drive

16384

POST dynamic gating test

Controller failure

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes