Electrical System

99

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

32768

Instantaneous under volt-
age

Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

1

Controller over voltage

Batteries over charged,
usually from regen. brak-
ing

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

2

Phase over current

Motor pulling too much
current, short bursts

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

4

Current sensor calibration

Internal controller issue

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

8

Not used

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

16

Controller temperature is

over 100

o

C

Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller

Stopped: Right hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

32

Motor hall sensor fault

Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

64

Controller under voltage

Battery voltage too low,
poor connection, corrosion

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes

Advertising