Electrical System

97

Blades off: Left Deck Fault
Blades off: Right Deck
Fault

Operator error

Disables Blades

2

One or both of the deck
motors are pulling 110
amps or more

Too much material being
cut, build up of clippings
under the deck, binding of
the motor, faulty motor or
a faulty controller

Blades off: Left Deck Fault
Blades off: Right Deck
Fault

Operator error

Disables Blades

16

One or both of the deck

controllers are at 100

o

C

or more

Too much material being
cut, build up of clippings
under the deck, binding of
the motor, faulty motor or
a faulty controller

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

1

Controller over voltage

Batteries over charged,
usually from regen. brak-
ing

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

2

Phase over current

Motor pulling too much
current, short bursts

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

4

Current sensor calibration

Internal controller issue

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

8

Not used

Stopped: Left hub fault /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

16

Controller temperature is

over 100

o

C

Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes