Cub Cadet RZT-S Zero Electric User Manual

Page 110

Advertising
background image

RZT-S Zero

10
6

Stopped: Right wheel
comm fault / Restart, if
problem persists contact
service

Fault

Disables Blades and Drive

256 (or no code
if VCM timed
out and is not
able to read a
fault code from
the controller.)

Network communications
timeout

Disconnected harness
connector, damaged har-
ness, corrosion

Stopped: Left deck comm
fault / Restart, if problem
persists contact service

Fault

Disables Blades and Drive

256 (or no code
if VCM timed
out and is not
able to read a
fault code from
the controller.)

Network communications
timeout

Disconnected harness
connector, damaged har-
ness, corrosion

Stopped: Right deck
comm fault / Restart, if
problem persists contact
service

Fault

Disables Blades and Drive

256 (or no code
if VCM timed
out and is not
able to read a
fault code from
the controller.)

Network communications
timeout

Disconnected harness
connector, damaged har-
ness, corrosion

Stopped: Contactor tips
welded closed / Restart, if
problem persists contact
service

Fault

Disables Blades and Drive

VCM is still powered up,
but the RUN switch is in
the off position, and none
of the drives are producing
regen current.

VCM is being powered by
current back feeding
through welded contactor
tips.

Stopped: Self-test failure /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

Interlock1
code 64

Microelectronic hardware
failure detected in CPU of
VCM

Internal failure

Stopped: Self-test failure /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

Interlock1
code 128

RAM in safety critical
memory changed unex-
pectedly

Internal failure

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes