Electrical System

10
3

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

16

Controller temperature is

over 100

o

C

Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault Disables

Blades 32

Motor

hall

sensor fault

Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

64

Controller under voltage

Battery voltage too low,
poor connection, corrosion

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

128

POST static gating test

Controller failure

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

512

Instantaneous phase over
current

Motor pulling too much
current, short bursts

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

1024

Motor has reached at tem-

perature of 105

o

C

Motor over loaded, faulty

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

2048

Throttle voltage outside
range

N/A

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault Disables

Blades 4096

Instantaneous

controller

over voltage

Batteries over charged,
usually from regen. brak-
ing

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

8192

Internal error

Controller failure

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes