Electrical System

59

• 150 amp main system fuse: This fuse is in-line on

the positive cable, between the battery pack and
the control panel. See Figure 5.4.

NOTE: If this fuse is blown, there is a major short in the

system. Check for chaffed wires or a shorted bat-
tery pack before replacing the fuse.

NOTE: The torque on the main fuse connections is 45 - 55

in lbs (5 - 6 Nm).

• Key switch: The key switch is a custom, two pin

key switch that is similar in appearance to most
MTD key switches. See Figure 5.5.

NOTE: This is a 48 volt system. DO NOT try to replace the

key switch with an after market key switch. The 48
volts can cause the after market switch to fail.

• Deck motors: The deck motors are 3-phase,

brushless DC motors with a keyed shaft.
See Figure 5.6.

• A 748-0376E blade adapter fits over the shaft to

mount a blade.

NOTE: The blades used on the RZT-S Zero are specifi-

cally designed for these mowers to maximize run
time and cut performance. Do not use after-market
blades.

NOTE: The motor harness is part of the motor and can not

be serviced. Any damage to the wires or the con-
nector and the whole motor will need to be
replaced.

Figure 5.4

150 Amp fuse

Figure 5.5

Key switch

Figure 5.6

Deck motor