13

Cabling
Installation

NOTE:

The HI 3000 instrument transmits data only over
a serial connection, it does not receive data.

RS 232 Connection Pinout

FIG. 24: SERIAL PORT CONNECTION

Reading left to right when viewing the rear panel from the
back.

Hardware Requirements:

Serial Cable with nine pin connector.

-JB Option Wiring

FIG. 25: -JB OPTION CONNECTIONS

Step 5. Connect the load cell cable wires to the terminal

blocks in accordance with the Load Cell manufac-
turers color code.

Step 6. Plug the terminal blocks into Channels 1 thru 4 con-

nectors on the rear panel. Write down which load

cell is connected to Channel 1, Channel 2, Channel
3, Channel 4 for future reference.

NOTE:

If you have one load point you must plug it into
Channel 1. If you have more than one load point
you must make sure that you plug one of the load
points into Channel 1.

Step 7. If you only have 3 load cells, do not use Channel 4.
Step 8. For more information concerning Non-C2 Load

Cell connections, consult the HI 3000 Series Ser-
vice Manual.

Ethernet Cable Connection and Setup

Hardware Requirements:

Ethernet Card - 10/100 Base T
Ethernet Cable w/RJ 45 connector.

Step 1. Plug the RJ45 connector into the Ethernet Connec-

tion at the rear panel of the instrument or the Junc-
tion Box. (See Fig. 26)

Plugging the RJ45 connector into an instru-
ment with an HI 3000-RC environmental rear
cap does not require removal of the cover. Use
needle nose pliers to hold the back of the con-
nector. While holding the connector with the
pliers, pass the connector through the access
port and press the connector into the RJ45 con-
nector at the rear of the instrument.

When removing the connector you will need to
use a small screw driver and needle nose pliers.
While holding the back of the RJ45 connector
with the pliers, use the screw driver to push
down on the latch at the top of the connector.
This releases the connector. Pass the connector
back through the access port.

FIG. 26: REAR PANEL/ETHERNET RJ 45

CONNECTION

Step 2. At the front panel push the Setup button. The Con-

figuration Menu appears. (See Fig. 27)

Pin Number

Connection

1

Iso Grnd

2

Grnd

3

Rxd

4

Txd

5

V+ (5VDC)

Table 3: Serial Port Pinout

S

h

ie

ld

-C

2

+C

2

-E

xc

-S

en

-S

ig

+S

ig

+S

e

n-

+E

x

c

S

hie

ld

-C

2

+C2

-E

xc

-S

en

-S

ig

+S

ig

+S

e

n-

+E

x

c

S

h

ie

ld

-C

2

+C

2

-E

xc

-S

en

-S

ig

+S

ig

+S

e

n-

+E

x

c

S

h

ie

ld

-C

2

+C

2

-E

xc

-S

en

-S

ig

+S

ig

+S

e

n-

+E

x

c

Channel 2

Channel 3

Channel 4

Channel 1

Printer/Display

Ethernet

SMM

Devicenet

Ne

u

Li

n

e

Gn

d

Is

o

Gn

d

Rx

d

Tx

d

V+

T/R

LINK

Advertising