Step 2. Select the Node address for the HI 3000 Series.

(See below) This can be done before or after Initial-
ization.

Step 3. Cycle power, or perform the two previous steps

before powering up your network. Address selec-
tion can only occur after cycling the power. Make
sure that the software you use will detect the values
as you have set them.

CAUTION: T

HE

ADDRESS

SHOULD

NEVER

BE

CHANGED

DURING

OPERATION

. I

F

THE

ADDRESS

IS

MODIFIED

WHILE

THE

POWER

IS

ON

,

AN

INTERNAL

ERROR

COULD

BE

GEN

-

ERATED

AND

THE

MODULE

DISCONNECTED

FROM

THE

NET

-

WORK

.

NOTE:

Profibus-DP provides a very flexible network
solution. In addition to the basic guideline pro-
vided in this manual, your installation could
require procedures that are beyond the scope of
this manual. For more information and to locate
lists of links to other sources of Profibus-DP
information, check the Profibus website at http://
www.profibus.com.

Step 4. Complete any additional configuration that is

required by your PLC for initialization. Our initial-
ization example is for a Siemens PLC. Your PLC
initialization requirements may differ.

Step 5. Install the *.GSD file for the HI 3000 Series Instru-

ment you connected to the Profibus Network.

Initialization Procedures

NOTE:

The examples provided are taken from the Sie-
mens Step 7™, Simatic Manager Software. Your
software will vary from these procedures. Step
7™ is a trademark of the Siemens Corporation.

Step 1. In the Siemens Step 7™, Simatic Manager open the

Hardware Catalog. (See Fig. 141)

FIG. 141: HARDWARE CATALOG/SELECTING

ANYBUS-S PDP FOLDER

Step 2. Click on the “+” to expand the Additional Field

Devices Folder. (See Fig. 141)

Step 3. Click on the “+” to expand the General Folder. (See

Fig. 141)

Step 4. Highlight the CPU you selected in the UR dialog

box.

Step 5. Double Click on ANYBUS-S PDP or drag and drop

the ANYBUS-S PDP folder to the Profibus-DP
Network. The Parameters dialog box appears. (See
Fig. 142)

Step 6. You can set the address of the instrument here if

necessary.

FIG. 142: ANYBUS-S PDP PARAMETERS DIALOG

BOX

Step 7. Click on “+” to expand the ANYBUS-S PDP

folder. (See Fig. 143)