Led 3 - network status, Led 4 - activity, Profibus option card installation – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 40: Profibus connection and setup, Hardware requirements, Software requirements, Cabling guidelines, Led 3 - network status led 4 - activity, Hardware requirements: software requirements, Ofibus db9 serial connector with slide

Advertising
background image

HI-3000 Series

26

Operation and Installation

LED 3 - Network Status

LED 3 Configuration

LED 4 - Activity

LED 4 Configuration - This LED flashes
green each time a packet is received or
transmitted.

Profibus Option Card Installation

CAUTION: M

AKE

SURE

THAT

YOU

USE

AN

ANTI

-

STATIC

STRAP

WHEN

INSTALLING

THE

P

ROFIBUS

O

PTION

C

ARD

.

Step 1. Position the Profibus Option Card with the back

plane connector facing Option Slot #0.

NOTE:

You can only use Option Slot #0 when installing
the Profibus.

Step 2. Slide the Profibus Option Card into Slot #0.
Step 3. Push the Profibus card up against the back plane

and gently press until the card connector seats in the
back plane connector.

Step 4. Use a phillips head screw driver and install the two

(2) screws that fasten the Profibus card panel to the
HI 3000 Instrument Chassis.

Step 5. Tighten the screws until the Profibus panel is snug.

Do not overtighten.

Profibus Connection and Setup

Hardware Requirements:

Hardy Profibus Option Card

Profibus Cable with DB9 Serial Connec-
tors on both ends. It is recommended that
you use a Serial Connector with a slide
switch to terminate an instrument that is
located at the end of a Fieldbus (Profibus)
Network. (See Fig. 74)

NOTE:

The Profibus-DP cable must conform to the
PROFIBUS-DP EN 50 170 Specification for
Cable.

FIG. 74: PROFIBUS DB9 SERIAL CONNECTOR

WITH SLIDE SWITCH/MALE

Software Requirements:

Siemens Step 7™, Simatic Manager or
equivalent.

Hardy *.GSD File (Available on the HI
3000 CD or current.GSD file can be down-
loaded from the Hardy Website (http://
www.hardyinst.com) or the Profibus Web
Site (http://www.profibus.com/librar-
ies.html)

Cabling Guidelines

1.

The Trunk Line is the main network cable and anchors
the two ends of the network.

2.

A Drop Line is the network branch cable between the
trunk line tap or junction box and the HI 3000 Series
instrument. The baud rate selection can affect and/or
restrict each of the following variables:

Steady Red

Major Fault

A major internal error has been
detected

Flashing
Green/Red

Self-Test

The module is performing a power on
self test

State

Summary

Description

Steady Off

No Power
or no IP
address

The module has no power or no IP
address has been assigned

Steady Green

Connected

The module has at least on estab-
lished EtherNet/IP connection

Flashing
Green

No Con-
nections

There are no EtherNet/IP connections
established to the module

Flashing Red

Connec-
tion Time-
out

One of more of the connections in
which this module is the target has
timed out. This state is only left if all
timed out connections are re-estab-
lished or if the module is reset.

Steady Red

Duplicate
IP

The module has detected that its IP
address is already in use

Flashing
Green/Red

Self-Test

The module is performing a power on
self test

TABLE 11: LED 3 CONFIGURATION

State

Summary

Description

TABLE 10: LED 2 CONFIGURATION

ON

OF
F

S

IEM
EN
S

Slide
Switch

Advertising