HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-4

Block Read
Command Number
2: Setpoint Relay
Parameter

BLOCK READ COMMAND NUMBER 2: Setpoint Relay Parameters

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 2 (decimal)

bit 0

0

bit 1

1

bit 2

0

bit 3

0

bit 4

0

bit 5

0

bit 6

0

bit 7

0

Indicator Group 2 Status

bit 8

Weight currently displayed in pounds units

bit 9

Zero Track feature enabled

bit 10

Reserved for future use

bit 11

Current gross weight = 0

bit 12

Weight in motion, i.e. changing

bit 13

Gross weight currently displayed

bit 14

Net weight currently displayed

bit 15

Weight currently displayed in kilogram units

Note: A returned value of “99” (decimal) indicates an error.

1

0

Relay Status

bit 0

Relay #8 status (on/off)

bit 1

Relay #7 status (on/off)

bit 2

Relay #6 status (on/off)

bit 3

Relay #5 status (on/off)

bit 4

Relay #4 status (on/off)

bit 5

Relay #3 status (on/off)

bit 6

Relay #1 status (on/off)

bit 7

Relay #2 status (on/off)

bit 8 - 15

Setpoint description byte A (See Table 5-4 & 5-5)

1

1

bits 0-7

Setpoint description byte B (See Table 5-4 & 5-5)

bits 8-15

Setpoint description byte C (See Table 5-4 & 5-5)

1

2

Deadband value for setpoint #1
Deadband value for setpoint #2
Deadband value for setpoint #3
Deadband value for setpoint #4
Deadband value for setpoint #5
Deadband value for setpoint #6
Deadband value for setpoint #7
Deadband value for setpoint #8

2
2
2
2
2
2
2
2

3
5
7
9
11
13
15
17

Preact value for setpoint #1
Preact value for setpoint #2
Preact value for setpoint #3
Preact value for setpoint #4
Preact value for setpoint #5
Preact value for setpoint #6
Preact value for setpoint #7
Preact value for setpoint #8

2
2
2
2
2
2
2
2

19
21
23
25
27
29
31
33