Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 28

Advertising
background image

HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-8

TABLE 5-8: BLOCK READ COMMAND NUMBER 5: CALIBRATION PARAMETERS

Block Read
Command Number
6: Configuration of
Rate-of-Change

TABLE 5-9: BLOCK READ COMMAND NUMBER 6: CONFIGURATION OF RATE-OF-CHANGE

Motion Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing
range

1

4

Zero Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing range

1

5

Number of readings averaged: A value from 1 to 200
Note: Number of averages will temporarily read 200 if the instrument was in the CAL menu while
this block read occurred.

1

6

Span weight value or C2

®

, Second Generation reference point value‘‘

2

7

Scale Capacity (Full limit of scale): A 20 bit number in proper integer format

2

9

Mid-point Linearity Calibration Value: A 20 bit number in proper integer format

2

11

TOTAL NUMBER OF WORDS

13

BLOCK READ COMMAND NUMBER 5:Calibration Parameters

START

WORD DEFINITIONS:

#WORDS

WORD

BLOCK READ COMMAND NUMBER 6: Configuration of Rate-of-Change

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 6 (decimal)

bit 0

0

bit 1

1

bit 2

1

bit 3

0

bit 4

0

bit 5

0

bit 6

0

bit 7

0

bits 8 - 15

Reserved for future use

1

0

Displayed Rate-of-Change time units: A value of 0 to 2 (0=sec, 1=min, 2=hr)

1

1

Rate-of-Change timebase evaluation period in seconds

0 = 1 second

4 = 5 seconds

8 = 15 seconds

12 = 240 seconds

1 = 2 seconds

5 = 6 seconds

9 = 30 seconds

13 = 450 seconds

2 = 3 seconds

6 = 10 seconds

10 = 60 seconds

14 = 900 seconds

3 = 4 seconds

7 = 12 seconds

11 = 120 seconds

15 = 1800 seconds

1

2

TOTAL NUMBER OF WORDS

3

Advertising