HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-20

Block Write
Command Number
55: Calibration
Parameters

TABLE 5-22: BLOCK WRITE COMMAND NUMBER 55: CALIBRATION PARAMETERS

BLOCK WRITE COMMAND NUMBER 55: Calibration Parameters

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 55 (decimal)

bit 0

1

bit 1

1

bit 2

1

bit 3

0

bit 4

1

bit 5

1

bit 6

0

bit 7

0

bit 8 - 15

Reserved for future use

1

0

Units of Measure:

bits 0 - 7

0 = pounds, 1 = kilograms

Decimal point position (places to right of decimal):

bits 8 - 15

A value from 0 to 4

1

1

Totalizer decimal point position (places to right of decimal):

bits 0 - 7

A value from 0 to 4

C2™, Second Generation Calibration

bits 8 - 15

Load Cell Count (set to zero for Hard Cal)

1

2

Display Graduation Size (“count by”): A value of 1,2,5,10,20,50,100,200 or 500

1

3

Motion Tolerance: A sixteen bit value representing the lower 16 bits of the 20 bit
internal weighing range

1

4

Zero Tolerance: A sixteen bit value representing the lower 16 bits of the 20 bit inter-
nal weighing range

1

5

Number of readings averaged: A value from 1 to 200

1

6

Span weight value (Use one of the following methods. Method one, with C2, Sec-
ond Generation Calibration: Use the C2 reference point when using C2 load cells.
Method two: use test weights for calibration) A 20 bit number in proper integer for-
mat

2

7

Scale Capacity (Full limit of scale): A 20 bit number in proper integer format

2

9

Mid-point Linearity calibration value: A 20 bit number in proper integer format

2

11

TOTAL NUMBER OF WORDS

13