HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-12

Block Read
Command Number
11: Auto Zero
Tolerance

TABLE 5-14: BLOCK READ COMMAND NUMBER 11: AUTO ZERO TOLERANCE

Block Read
Command Number
12: Integrated
Technician

HI 2151/30WC Only.

NOTE:

Integrated Technician is not used with the HI 2151/20WC

BLOCK READ COMMAND NUMBER 11: Auto Zero Tolerance

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 11 (decimal)

bit 0

1

bit 1

1

bit 2

0

bit 3

1

bit 4

0

bit 5

0

bit 6

0

bit 7

0

bits 8 - 15

Reserved for future use

1

0

Auto Zero Tolerance

A 16 bit number in proper integer format

1

1

TOTAL NUMBER OF WORDS

2