Chapter 5 - block transfers – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 41

Advertising
background image

Chapter 5 - Block Transfers

5-21

Block Write
Command Number
56: Configuration of
Rate-of-Change

TABLE 5-23: BLOCK WRITE COMMAND NUMBER 56: CONFIGURATION OF RATE-OF-CHANGE

BLOCK WRITE COMMAND NUMBER 56: Configuration of Rate-of-Change

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 56 (decimal)

bit 0

0

bit 1

0

bit 2

0

bit 3

1

bit 4

1

bit 5

1

bit 6

0

bit 7

0

bit 8 - 15

Reserved for future use

1

0

Displayed Rate-of-Change time units: A value of 0 to 2 (0 = sec, 1 = min, 2 = hr)

1

1

Rate-of-Change timebase evaluation period: A value of 0 to 15 from list below:

0 = 1 second

4 = 5 seconds

8 = 15 seconds

12 = 240 seconds

1 = 2 seconds

5 = 6 seconds

9 = 30 seconds

13 = 450 seconds

2 = 3 seconds

6 = 10 seconds

10 = 60 seconds

14 = 900 seconds

3 = 4 seconds

7 = 12 seconds

11 = 120 seconds

15 = 1800 seconds

1

2

TOTAL NUMBER OF WORDS

3