HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-10

TABLE 5-11: BLOCK READ COMMAND NUMBER 8: CONFIGURATION OF ANALOG OUTPUT

Block Read
Command Number
9: Configuration of
Standard RS232
Port (HI 2151/20WC
Only)

HI 2151/20WC Only.

Weight value represented by a zero scale analog output:

2

1

Weight value represented by a full scale analog output:

2

3

TOTAL NUMBER OF WORDS

5

BLOCK READ COMMAND NUMBER 8: Configuration of Analog Output

START

WORD DEFINITIONS:

#WORDS

WORD

BLOCK READ COMMAND NUMBER 9: Configuration of Standard RS232 Port

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 9 (decimal)

bit 0

1

bit 1

0

bit 2

0

bit 3

1

bit 4

0

bit 5

0

bit 6

0

bit 7

0

bits 8 - 15

Reserved for future use

1

0

Format of Communication:

bit 0

Print initiation (If configured as printer. 1 = print button
0 = continuous. If configured as bi-directional: 0 = print button,
1 = altered print).

bit 1

Setpoint, Deadbands, and Preact values transmitted

bit 2

Rate-of-Change transmitted

bit 3

Tare weight transmitted

bit 4

Net weight transmitted

bit 5

Gross weight transmitted

bit 6

Reserved for future use

bit 7

Reserved for future use

bits 8 - 15

Reserved for future use

1

1

Port Configuration

bits 0 - 7

A value of 0 or 1 [0=Bi-Directional, 1 = Printer (output) only]

Baud Rate

bits 8 - 15

A value of 0 to 5 (0 = 600, 1 = 1200, 2 = 2400, 3 = 4800,
4 = 9600, 5 = 19200)

1

2

Parity

bits 0 - 7

A value of 0 to 2 (0=None, 1 = 1 = Even, 2 = Odd)*

Stop Bits

bits 8 - 15

A value of 0 or 1 (0=one stop bit, 1 = two stop bits)*

*Note: Parameters are not used in the HI 2151/30WC

1

3