Block read command number 10: sticker value, Block read command number 10: sticker value -11, Chapter 5 - block transfers – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 31

Advertising
background image

Chapter 5 - Block Transfers

5-11

TABLE 5-12: BLOCK READ COMMAND NUMBER 9: CONFIGURATION OF STANDARD RS232 PORT

Block Read
Command Number
10: Sticker Value

HI 2151/20WC Only.

NOTE:

Sticker Value is not used in the HI 2151/30WC

TABLE 5-13: BLOCK READ COMMAND NUMBER 10: STICKER VALUE

Word Length

bits 0 - 7

A value of 0 or 1 [0 = seven bits, 1 = eight bits*

Handshake Control

bits 8 - 15

A value of 0 or 1 (0 = Hardware, 1 = Software

*Note: Parameters are not used in the HI 2151/30WC

1

4

Echo

bits 0 - 7

A value of 0 or 1 (0= Off, 1 = On)

Device Address

bits 8 - 15

A value from 0 to 99

1

5

TOTAL NUMBER OF WORDS

6

BLOCK READ COMMAND NUMBER 9: Configuration of Standard RS232 Port

START

WORD DEFINITIONS:

#WORDS

WORD

BLOCK READ COMMAND NUMBER 10: Sticker Value (HI 2151/20SC Only)

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 10 (decimal)

bit 0

0

bit 1

1

bit 2

0

bit 3

1

bit 4

0

bit 5

0

bit 6

0

bit 7

0

bits 8 - 15

Reserved for future use

1

0

Sticker Value

A 20 bit number in proper integer format

2

1

TOTAL NUMBER OF WORDS

3

Advertising