Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 42

Advertising
background image

HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION

5-22

Block Write
Command Number
57: BCD Output
Configuration

Block Write
Command Number
58: Configuration of
Analog Output

NOTE:

This command is only active if this option is installed in the HI 2151WC

BLOCK WRITE COMMAND NUMBER 57: BCD Output Configuration

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 57 (decimal)

bit 0

1

bit 1

0

bit 2

0

bit 3

1

bit 4

1

bit 5

1

bit 6

0

bit 7

0

Format of output:

bit 8

If set, will update BCD output when “print” button or remote
function is activated.

bit 9

Reserved for future use

bit 10

If set, will output weight data currently displayed

bit 11

If set, will output Tare Value

bit 12

If set, will output Net Weight

bit 13

If set, will output Gross Weight

bit 14 - 15

Reserved for future use

1

0

TOTAL NUMBER OF WORDS

1

TABLE 5-24: BLOC WRITE COMMAND NUMBER 57: BCD OUTPUT CONFIGURATION

BLOCK WRITE COMMAND NUMBER 58: Configuration of Analog Output

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 58 (decimal)

bit 0

0

bit 1

1

bit 2

0

bit 3

1

bit 4

1

bit 5

1

bit 6

0

bit 7

0

Weight parameter to be transmitted

bits 8 - 15

A value from 0 to 4 (0 = Gross, 1 = Net, 2 = Rate-of-Change,

3 = Peak Force, 4 = Totalized Amount)

1

0

Advertising