Chapter 5 - Block Transfers

5-23

TABLE 5-25: BLOCK WRITE COMMAND NUMBER 58: CONFIGURATION OF ANALOG OUTPUT

Block Write
Command Number
59: Configuration of
Standard RS232
Port

HI 2151/20WC Only.

Weight value represented by a zero scale analog output:

2

1

Weight value represented by a full scale analog output:

2

3

TOTAL NUMBER OF WORDS

1

BLOCK WRITE COMMAND NUMBER 58: Configuration of Analog Output

START

WORD DEFINITIONS:

#WORDS

WORD

BLOCK WRITE COMMAND NUMBER 59: Configuration of Standard RS232 Port

START

WORD DEFINITIONS:

#WORDS

WORD

Command number: A value of 59 (decimal)

bit 0

1

bit 1

1

bit 2

0

bit 3

1

bit 4

1

bit 5

1

bit 6

0

bit 7

0

bits 8 - 15

Reserved for future use

1

0

Format of Communication

bit 0

Print Initiation (1 = altered print, bit 6 must = 0)

bit 1

Setpoint, Deadbands, and Preact values transmitted

bit 2

Rate-of-Change Transmitted

bit 3

Tare Weight Transmitted

bit 4

Net Weight Transmitted

bit 5

Gross Weight Transmitted

bit 6

Print initiation (0 = continuous, 1 = print button, bit 0 must = 0

bit 7 - 15

Reserved for future use

1

1

Port Configuration

bits 0 - 7

A value of 0 or 1 (0 = Bi-Directional, 1 = Printer (output) only)

Baud Rate

bits 8 - 15

A value of 0 to 5 (0 = 600, 1 = 1200, 2 = 2400, 3 = 4800,

4 = 9600, 5 = 19200

1

2

Parity

bits 0 - 7

A value of 0 to 2 (0 = None, 1 = Even, 2 = Odd)*

Stop Bits

bits 8 - 15

A value of 0 or 1 (0 = one stop bit, 1 = two stop bits)*

*Note: Parameters not set by HI 2151/30

1

3

Word Length

bits 0 - 7

A value of 0 or 1 (0 = seven bits, 1 = eight bits)*

Handshake Control

bits 8 - 15

A value of 0 or 1 (0 = Hardware, 1 = Software)

*Note: Parameters not set by HI 2151/30

1

4

Advertising