Peak Hold (Mode 5)

The peak hold mode maintains the peak weight detected by the weight indicator.

Display Peak Weight
Use the GROSS/NET key to scroll thru the display options as follows:

Initial mode:

Display live gross weight. Gross LED on.

First GROSS/NET press: Display live net weight.

Net LED on.

Next GROSS/NET press: Display gross peak weight. Gross LED flashing.

Next GROSS/NET press: Display net peak weight.

Net LED flashing.

Next GROSS/NET press: Returns to live gross weight. Gross LED on.

Etc.

Print Peak Weight
Use function 65 (Configure Print Formats) to format the print output using page 1:

Print Item 19:

Print Gross Peak weight on page 1. (Default Prints Gross Peak)

Print Item 20:

Print Net Peak weight on page 1.

Over / Under Checkweigh (Mode 6)

The Over/Under Checkweigh mode uses 3 TTL outputs to indicate scale weight under setpoint1,

between setpoint 1 & setpoint 2, or over setpoint 3.

Fixed register 43 = Setpoint 1 (Under)

Fixed register 44 = Setpoint 2 (Over)

TTL output 1 = Under setpoint 1

TTL output 2 = Between setpoint 1 & 2

TTL output 3 = Over

NOTE: if setpoint 1 = setpoint 2 then TTL 1 = under setpoint, TTL 2 = over setpoint.

This mode prompts for additional information when mode number is entered in the

configuration function. (See

Set Mode Of Operation at beginning of this chapter.)

The display prompts "SP 1". Press the

enter key. The current under weight setpoint (register 43)

is displayed. Use the

item, +, and - keys to change the setpoint weight. Press the enter key to

accept the displayed setpoint weight.

The display prompts "SP 2". Press the

enter key. The current over weight setpoint (register 43)

is displayed. Use the

item, +, and - keys to change the setpoint weight. Press the enter key to

accept the displayed setpoint weight.