Industrial Data Systems IDS 410 User Manual

Page 49

Advertising
background image

IDS 410/422 User's Manual

48

Diagnostic Test 3: Serial Com Port 1 - Transmit Data

This test transmits data out of serial communications port 1. The display prompts: "OUT 0".

Press the

enter key to send data. Serial Port 1 transmits "1234567890ABCDEF" and prompts

"OUT 1" to indicate that 1 transmission has occurred. Press the

enter key again or press the

clear key to exit diagnostic test 3.

NOTE: If the error message "Er CtS" appears, the data can not be transmitted because the

handshake signal, clear-to-send (TB1 pin 7), is low or not connected. If clear-to-send is not used,

jumper it to data-terminal-ready (TB1 pin 4)

Diagnostic Test 4: Serial Com Port 2 - Display Input Data

This test displays serial data as it is received by serial communications port 2. The

numeric display has limited alpha display capability, however numeric and some alpha

characters are legible. If all data being received is unintelligible, the baud rate is probably

incorrect. If nothing is displayed on the display, then check the following:

1. RS232/RS485 jumper on the main circuit board.

2. Cabling between the communicating units.

3. Make sure the sending unit is actually sending data. Press the

clear key to exit

diagnostic test 4.

Diagnostic Test 5: Serial Com Port 2 – Display Errors

This test displays the number of framing and parity errors that are detected in the input data

stream. The error count is set to zero when entering this test. New errors are displayed as

"PxxFxx" where Pxx is the number of parity errors and Fxx is the number of framing errors. If

the error count exceeds 99, the display will remain at 99. Press the

clear key to exit Diagnostic

test 5.

Diagnostic Test 6: Serial Com Port 2 - Transmit Data

This test transmits data out of serial communications port 2. The display prompts: "OUT 0".

Press the ENTER key to send data. Serial Port 2 transmits "1234567890ABCDEF" and

prompts "OUT 1" to indicate that 1 transmission has occurred. Press the ENTER key again or

press the

clear key to exit diagnostic test 6.