IDS 410/422 User's Manual

56

HARDWARE INSTALLATION AND WIRING

This section describes installation and wiring information for the interface ports. There are two

bi-directional serial ports, digital port with 3 TTL inputs, 3 TTL outputs, and one load cell input

port. The serial ports are used to interface to a printer and to a host device or PC for continuous

output. The TTL outputs and inputs are used for remote switch input and relay control. The load

cell input is used to interface to the scale platform.

Load Cell Connector – TB1

NOTE: Remove jumpers JP1 and JP2 to enable SENSE LINES for 6 wire load cells. Wire the

sheilding from the load cells to the chassis not TB1 pin 7.

Load Cell Terminal Block – TB1

Pin #

Signal Name

1

+ Signal

2

- Signal

3

+ Excitation

4

+ Sense

5

- Sense

6

- Excitation

7

Analog ground

(NOT FOR SHIELD)

Power Source AC / DC

The unit come standard with an onboard transformer the AC interface connector is a 3 pin

Molex type, this connects to the motherboard where the 3 pin Molex header is mounted

on the board marked A/C power.

For DC power applications there ia a 2 position terminal block marked PWR-DC.

Note the polarity of the terminals the positive is marked as ( + ) the negative ( - ).

The DC power input will exept +12 to +28 VDC. Remove AC power before wiring

for DC.

I/O Port Connector - TB 3

The I/O port connector has Com Ports 1 and 2 and the digital TTL inputs.

Pin #

Signal Name

1

+5V (TX- 20 mA CL)

2

TXD 1 (RS232)

3

RXD1 (RS232)

4

Soft +5 volts (220 ohm to +5V)

5

GND

6

CL TX +