Function 61: Calibrate Scale - Span First

Use function 61 to calibrate the scale by reading the span first and then reading the deadload.

(This function does not change the internal A/D deadload factor). Set the Scale Operation

Parameters before using function 61. Best results are obtained when the IDS 410/422 and load

cells have reached thermal equilibrium (power applied for approximately 30 to 120 minutes

depending on load cell size).

1 Hold the GROSS/NET key down and press the UNITS key to enter configure mode.

2 Enter CFG 61. The IDS 410/422 prompts "CALib". Place the calibration weight on the

scale. Enter the calibration weight using the numeric keypad. Press the ENTER key. The IDS

410/422 reads the calibration weight.

3 The IDS 410/422 prompts "dEAdld". Remove all weight from the scale. Press the ENTER

key. The IDS 410/422 reads the scale's deadload weight.

4 The IDS 410/422 prompts "CFG 61". Press the CLEAR key to exit the configure mode.

Function 62: Calibrate Deadload Only

Use function 62 to re-calibrate the deadload weight without affecting the span calibration. (Does

not change internal A/D deadload factor).

1 Hold the GROSS/NET key down and press the UNITS key to enter configure mode.

2 Enter CFG 62. The IDS 410/422 prompts "dEAdld". Remove all weight from the scale.

Press the ENTER key. The IDS 410/422 reads the scale's deadload weight.

3 The IDS 410/422 prompts "CFG 62". Press the CLEAR key to exit the configure mode.

Function 63: Adjust Gain Calibration

Use function 63 to make small adjustments to the span calibration. Zero the scale and then place

a known weight on the scale. When this function is selected, the

item key (alternate function key)

can be pressed to change the gain adjustment factor between (1-10-100-1000-10000) the default

adjustment factor is 1000.

1 Hold the GROSS/NET key down and press the UNITS key to enter configure mode.

2 Enter CFG 63. The IDS 410/422 displays the weight on the scale in (1- 10000) graduation

increments depending on the gain adjustment factor selected through the

item key. The least

significant 2 display digits show the graduation increments.