DIAGNOSTIC TESTS

The DIAGNOSTIC TESTS are accessed using configuration function 69. Hold the

GROSS/NET key down and press the UNITS key to enter configure mode. The display prompts

"CFG xx" where xx is the currently selected parameter. Enter

69 and press the ENTER key to

access the DIAGNOSTIC TESTS.

The display prompts "diA xx" where xx is the last selected diagnostic function. Select a test

number from the table below. Enter the test number and press the ENTER key.

Table of Diagnostic Tests

Test No.

Hardware Tested

Description

1

Serial Com. Port 1

Display input data.

2

Serial Com. Port 1

Display input error count.

3

Serial Com. Port 1

Transmit data.

4

Serial Com. Port 2

Display input data.

5

Serial Com. Port 2

Display input error count.

6

Serial Com. Port 2

Transmit data.

7

TTL I/O 1,2 &3.

Activate TTL out / in

8

A/D converter

Display raw conversion data.

9

Ram Memory

Test memory for errors.

10

Display

Turn on all LED’s and display segments.

11

EAROM data

Print the EAROM configuration data.

12

Serial Com. Port 1

Transmit/Receive loop-back test.

13

Serial Com. Port 2

Transmit/Receive loop-back test.

Diagnostic Test 1: Serial Com Port 1 - Display Input Data

This test displays serial data as it is received by serial communications port 1. The numeric

display has limited alpha display capability, however numeric and some alpha characters are

legible. If all data being received is unintelligible, the baud rate is probably incorrect. If nothing

is displayed on the display, then check the following:

1. RS232/Current switch on the main circuit board.

2. Cabling between the communicating units.

3. Make sure the sending unit is actually sending data.

Diagnostic Test 2: Serial Com Port 1 – Display Errors

This test displays the number of framing and parity errors that are detected in the input data

stream. The the error count is set to zero when entering this test. New errors are displayed as

"PxxFxx" where Pxx is the number of parity errors and Fxx is the number of framing errors. If