Futaba 4GRS User Manual

Page 56

Advertising
background image

(HOME screen)

100

*This function cannot be used with "TH-STK : F10".

56

Fu

nc

tio

n

End Point Adjuster "END POINT"

(Preparation)
- Before setting the throttle end point adjustment (END POINT),

set the throttle ATL (initial setup: DT4) to the maximum throttle
angle position 100%.

- Select the setting item "FWD" by the (JOG) button up or down

operation and make the following adjustments:

1

Throttle (full power) adjustment

Push the throttle stick forward to the full power
position and use the (+) or (-) buttons to ad-
just the throttle angle. However, when using an
FET amp, set to 100%.

2

Throttle (brake side/reverse side) adjustment

Pull the throttle stick full back to brake/reverse
and use the (+) or (-) buttons to adjust the
throttle angle. However, when using an ESC,
set to 100%.

3

When completed, return to the MENU1 screen by pressing

the (JOG) button.

Throttle (END POINT) adjustment

1

3rd/4th channel servo (up position) adjustment

Select the setting item "CH3 or CH4 UP" using the (JOG)
button up or down operation, and set the 3rd or 4th channel
dial fully to the up using (+ side) and use the (+) or (-) but-
tons to adjust the servo angle.

2

3rd/4th channel servo (down position) adjustment

Select the setting item "CH3 or CH4 DWN" using the (JOG)
button up or down operation, and set the 3rd or 4th channel
dial fully to the up position (- side) and use the (+) or (-) but-
tons to adjust the servo angle.

3

When completed, return to the MENU1 screen by pressing

the (JOG) button.

3rd & 4th channel servo (END POINT) adjustment

Adjust button
- Use the (+) and (-) buttons to

make adjustments.

- Return to the initial value

"100" by pressing the (+) and
(-) buttons simultaneously for
about 1 second.

Throttle EPA
THR FWD :0~120
THR BRK :0~120
Initial value :100

Adjust button
Adjust with the (+) and (-) but-

tons.

- Return to the initial value "100"

by pressing the (+) and (-) but-
tons simultaneously for about 1
second.

3rd & 4th channel EPA
CH3/CH4 UP

:0~120

CH3/CH4 DWN :0~120
Initial value :100

Advertising