Fail safe function "fail safe, Fu nc tio n, All channel) – Futaba 4GRS User Manual

Page 57

Advertising
background image

Press

Press

Press

Select
"FAIL SAFE"

Press

(HOME screen)

(MENU 2 screen)

(FAIL SAFE screen)

(MENU 1 screen)

cursor position [RT]

Setting item
MODE :F/S mode selection
POSI :F/S positon set
B-FS :B-FS set (throttle only)
VOLT :B-FS voltage set (throttle only)

57

Fu

nc

tio

n

Fail Safe Function "FAIL SAFE"

Fail Safe Function "FAIL SAFE"

(All channel)

Fail Safe Mode (F/S)

This function moves each servo to a preset position when the receiver does not receive a

clear signal from the transmitter.

-When the condition set at "FHSS" is Rx type, fail safe (F/S) can be set only for throttle (TH). Other channels are set to the

normal mode.
-The fail safe data is transferred from the transmitter to the receiver 10 seconds after the transmitter power is turned on. The

data is transferred every 5 seconds after that. Be careful because normally the transmitter power is turned on first and the re-

ceiver power is turned on next and the data is transferred for approximately 10 seconds after the receiver power is turned on.

-For gasoline engine cars, for safety we recommend that this fail safe function be used to set the throttle channel in the direc-

tion in which the brakes are applied.

Hold mode (HOLD)

This function holds the servo/s at the position they were in immediately before recep-

tion was lost. This applies to the T-FHSS type (R304SB...,etc.) and the S-FHSS type

(R2104GF...,etc.) receivers only. When the receiver used is an R603GF/2004GF or other

FHSS type, this function is not available.

Off mode (OFF)

In this model the receiver stops outputting a signal to the servos if the transmitter signal

is lost. The servos become effectively unpowered.
The F/S, HOLD, and OFF modes are automatically reset when signals from the trans-

mitter can be received again.

Battery fail safe function (BFS)

If the receiver battery voltage drops below a certain value when this function is enabled,

the throttle servo moves to the position set by fail safe function. When the battery volt-

age recovers, the battery fail safe function is automatically reset.

-This function cannot be used when the throttle (TH) is not set to fail safe (F/S).

-This function is for the T-FHSS type (R304SB...,etc.) and the S-FHSS type (R2104GF...,etc.) receiver only. It cannot be used

with the R603GF and R2004FG and other FHSS type.

Display to "FAIL SAFE" screen by the following method: