11.1.2 CFS 50K-3 models:

Set reference

 Reset balance to zero or tare the empty weighing container if necessary.

 Place on the weighing plate a known number (e.g. 10 items) of individual pieces

as a reference.
Wait for the stability display, than enter the number of individual items via the
numeric keypad.

Confirm within 5 sec by pressing

.


The balance determines the average piece weight.

Count the items

 Tare if necessary, place weighing good and read off the number of items.


When an optional printer is connected, the displayed value can be edited by

pressing

(menu settings „P mode“  „Print“  „Au OFF“, chap. 13.2).

Delete reference value

 Press