II - SPECIFICATIONS
– GENERAL (cont.)
Power Supply
Appliance – 120 Volts A.C. – 60 Hz.
Remote control 12 volt D.C. (Digital)
Safety Devices
Flame failure - Flame rod
Boiling protection - 203˚F
Remaining flame (OHS) 194˚F bi-metal switch
Fusible link
Automatic frost protection
- Bimetal sensor & anti-frost heaters
Combustion fan rpm check - integrated circuit
Over current - Glass fuse (3 amp)
Remote control cable
Non-polarized two core cable
Clearances from combustibles
Top of heater
12"
Front of heater
24"
Sides of heater
6"
Back of heater
0"
Ground
12"
Installations within RGB-25 Recess Box: Clearances
from combustibles to recess box top, bottom, back and
sides = 0"
Clearances from eaves,
Top of heater 36"
porches, overhangs