LAARS IGE-199C-5(N,X) - Service Manual User Manual

Page 35

Advertising
background image

3) Is the remote control normal?

No combustion (despite remote control indication)

1) Is the water flow sensor normal?

Check voltage between the two remote control cable

connectors.

a.

Check the voltage between terminals on the

remote control terminal mount D

1

.

Normal: 11 ~ 13 VDC
If normal, check for an open circuit or short before

replacing the remote control.
Faulty: Replace PCB.

(Service Procedure IGE-2, page 47)

Check the water flow sensor.

a.

Check the voltage at PCB connector B4 , red and

black wires.

Normal: 11 ~ 13 VDC or 5.8 ~ 6.4K Ω

If normal, check (b) below.

Faulty: Replace the PCB.

(Service Procedure IGE-2, page 47)

b.

Check the voltage at PCB connector B4, yellow and

black wires.

Normal: 4 ~ 7 VDC or 1M ~ 1.2M Ω.

If normal, proceed to check item 2 on next page.

Faulty: Replace the water flow sensor.

(Service Procedure IGE-2, page 47)

VI - TROUBLESHOOTING

(cont.)

35

Advertising
This manual is related to the following products: