II - SPECIFICATIONS

– GENERAL

Type of appliance

Temperature controlled continuous flow gas hot water system

Operation

With/without remote controls

Exhaust system

Direct Vent - Forced combustion

Model Type

Residential

Commercial

Maximum/Minimum

gas rate (Input Btu's)

199,000 Btu's – 15,000 Btu's Natural gas

199,000 Btu's – 15,000 Btu's Propane Gas

Thermal Efficiency

Natural Gas 84% Propane Gas 85%

Energy Factor (EF)

Natural Gas 0.82 Propane Gas 0.84

Capacity (Gallons 1st

Natural Gas 218 Propane Gas 227

Hour @ 90°F rise)

NO

x

Emissions (at 3% 02)

Less than 40 ppm

Hot water capacity (50°F rise)

0.5 to 6.5 GPM's

Setpoint Temperature

Factory setting - 120°F

(without remote)

Temperature range

BC-45-4US 96 - 120°F

MCC-45-4US 96 - 160°F

with remote keypads connected

BSC-45-4US 96 - 120°F

MC-45-4US 96 - 180°F

Approved gas type

Natural or Propane – Ensure unit matches gas supply type.

Installation

Outdoor installation ONLY

Dimensions

Height 23

5

8

"

Width 13

3

4

"

Depth 8

7

8

"

Weight

46 Lbs.

Noise levels

49 dB's

Connections

Gas supply

3

4

" MNPT

Cold water inlet

3

4

" MNPT

Hot water outlet

3

4

" MNPT

Ignition system

Direct electronic ignition

Electrical consumption

Operating

63 watts

Standby

5.5 watts

Anti-frost protection 84 watts

Water temperature control

Simulation feedforward and feedback

Water flow control

Water flow sensor and automatic electro-mechanical water

control device

Recommended Minimum water

supply pressure

20 PSI (recommend 50-80 PSI for maximum performance)

Maximum water supply pressure

150 PSI