III - MAIN COMPONENTS

(cont.)

5. Combustion Fan

Air for the combustion is supplied by a centrifugal fan

driven by a DC motor. After a pre-purge period of 0.2

seconds, the fan speed is controlled by the PCB to

provide the correct volume of air for combustion. The

calculation for the fan speed is based upon incoming

water temperature, water flow and the temperature

selected on the remote controls.

The actual speed of the motor is continuously monitored

by a magnetic pulse sensor.

This sensor emits (4) pulses per rotation of the fan. This is

the fan feedback or confirmation data processed by the PCB.

The fan speed is constantly correcting to provide optimum combustion conditions. In addition,

the fan speed will determine the opening degree of the modulating gas valve. This enables the

gas rate to always match the volume of air for combustion, as well as the input required to

heat the water.

1. Water Flow Sensor and Water Flow Control device

Water flow is detected by a turbine/magnetic pulse generating device. Water flows through the

turbine/magnetic sensor providing information to the PCB by generating a pre-determined number of

pulses in proportion to the water flow. These pulses are counted by the PCB – no pulse indicates no

water flow. The frequency of the magnetic pulses increases as the water flow increases, this enables

the PCB to calculate the exact water flow, and determine the water flow in gallons per minute. As

soon as the required water flow is detected, the PCB activates the combustion fan. The combustion

fan speed is monitored by a magnetic pulse sensor. The output from this sensor is processed by the

PCB which opens the gas modulating valve to a degree proportional to the fan speed.

See above for further details on the combustion fan.

The water flow control consists of a plug and barrel valve which is rotated by a motor to increase or

decrease the volume of water passing through the heat exchanger.

Automatic water flow control device