IGE - 7. Removal of Transformer:

CAUTION

120 volt potential exposure. Isolate the appliance

and reconfirm power has been disconnected

using a multimeter.

a.

Remove the combustion fan motor

assembly as described in section 5-a,b.

b.

Remove the two (2) Phillips screws to

release the transformer.

c.

Disconnect wiring harness connectors to

transformer and pull out towards you.

IGE - 8. Removal of Burner Manifold and the

Burner:

CAUTION

120 volt potential exposure. Isolate the appliance

and reconfirm power has been disconnected

using a multimeter.

a.

To remove the burner manifold, remove

(6) Phillip screws around the burner plate

as shown in the upper right picture.

b.

Remove the (3) Phillip screws at the gas

valve assembly.

c.

Grip the burner manifold and remove it

from the unit.

d.

To remove the burner assembly remove

(8) Phillip screws around the sight glass

panel. Remove this panel.

e.

Locate the (2) Phillip screws inside the

burner chamber that hold the burner

assembly in place. Remove these two

screws, grip the burner assembly and slide

it out of the combustion housing.

f.

If you need to remove each burner from

this housing remove the (2) Phillip screws

on each side of the burner, as shown

below.