LAARS IGE-199C-5(N,X) - Service Manual User Manual

Page 42

Advertising
background image

42

a.

# Disconnect the modulating valve festoon C2

terminals and measure the resistance at the terminals.

Normal: 67 ~ 81 Ω
If normal, check b.
Faulty: Replace gas valve.

(Service Procedure IGE-9, page 50)

b.

Re-connect terminal C2 and measure voltage

across the pink ~ pink wires when the unit is firing.
Normal: 2 ~ 15 VDC
If normal, check c below.

Faulty: Replace the PCB unit.

(Service Procedure IGE-2, page 47)

c.

Investigate the change in the manifold gas

pressure, when the remote control pre-set

temperature is altered from 96 ~ 140 ºF.
Normal: If the manifold pressure changes,

proceed to check item 4 below. DO NOT

adjust manifold pressures.

Faulty: Replace gas valve.

(Service Procedure IGE-9, page 50)

a.

# Disconnect connector B2 and measure the

resistance of the water flow servo, red ~ blue wires.
Normal: 22 ~ 26 Ω
If normal, proceed to b.
Faulty: Replace the water flow servo and sensor.

(Service Procedure IGE-2, page 47)

b.

Disconnect connector B2 , and measure the

voltage on the PCB unit side, were the orange

(+), and/or grey or black (-) wires connect to the board.

Normal: 3.3 ~ 4.5 VDC
If normal, proceed to c.
Faulty: Replace the PCB unit.

(Service Procedure IGE-2, page 47)

c.

With connector B

2

, connected (do not turn water

ON … wait for the water flow servo to return to

fully open), measure the voltage at the brown ~
grey wires.
Normal: 4 ~ 6 VDC vent limiter OFF
Faulty: Replace the water flow servo and sensor.

(Service Procedure IGE-2, page 47)

d.

With connector B2 , connected (do not turn

water ON… wait for the water flow servo to

return to fully open), measure the voltage at the

yellow ~ grey wires.
Normal: Less than 0.5 VDC when unit is set at
120 °F and there is no water flowing through the unit.

Faulty: Replace water flow servo and sensor.

(Service Procedure IGE-2, page 47)

3) Is the modulating valve operating normally? Error code 52

4) Is the water flow servo normal?

BEFORE CARRYING OUT CHECKS MARKED WITH A # SIGN, DISCONNECT THE POWER SUPPLY.