Warning – LAARS IGE-199C-5(N,X) - Service Manual User Manual

Page 47

Advertising
background image

47

WARNING

Dip switched #7 and #8 (combustion control switches) MUST

be returned to the "OFF" position, after setting pressures.

Dip switch #1 MUST be returned to the proper position

based upon the length of vent pipe (see page 13).

IMPORTANT

When dismantling the unit you should always isolate

the following items:

• Gas supply

• Electrical supply

• Water supply

• Drain all water from the appliance

The following diagram may be of assistance in locating

the above.

IGE - 1. Removal of the Front Panel

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a

multimeter.

a.

Remove the four (4) screws holding the

panel in place with a Phillips driver.

IGE - 2. Removal of PC board

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a

multimeter.

a.

Remove the two (2) screws holding the

PCB in place with a Phillips screw driver,

then pull the PC board out of the

appliance.

Disconnect all connectors.

IGE - 3. Removal of the Water Flow Sensor and

Water Flow Control Valve Assembly

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a

multimeter.

a.

Remove one (1) Phillips screw from the

heat exchanger water supply line and (1)

screw from the bypass valve assembly. Lift

the water line retainer up and over the

housing it attaches to, pull water line

towards yourself to disconnect water lines

from the assembly. Inspect o-rings for

damage, replace if defective.

Advertising
This manual is related to the following products: