background image

T

ESTING

AND

T

ROUBLESHOOTING

: T

EST

S

OFTWARE

0 2. 3 0 0 4. 0 3 00 . 5 4

101

4

0

Speed 5 Spin

(Full Speed)

Spin Speeds match those

available from console

012

All Motors

(synchronized)

013

All Motors

(unsynchronized)

912

End Motor

(in cal. position)

Table 4-4: VL6 Spot Luminaire Default Programs

Test Number

Test

Functions

31

Pan and Tilt

701

Pan 25% Speed

702

Tilt 25% Speed

39

VL6 Functions

703

Beam 25% Speed

705

Edge 25% Speed

706

Wheel 1

Continuous Frame

707

Wheel 2

Continuous Frame

Table 4-5: VL6B/VL6C/VL6C+ Spot Luminaire Mechanical Tests

Test Number

Test Parameter

Error Codes/Comments

000

Start Test

9

End Stop (OPEN)

103

No Reset (PAN)

001

Pan Test

8

End Stop (CLOSED)

203

No Reset (TILT)

002

Tilt Test

7

Speed 1

104

No Reset (PAN)

003

Beam Test

6

Speed 2

204

No Reset (TILT)

5

Speed 3 (45%)

4

Speed 4 (55%)

3

Speed 5 (65%)

2

Speed 6 (75%)

1

Speed 7 (85%)

0

Speed 8 (FULL SPEED)

004

Lens Test

7

All move to front EOT, Lens

1 cycles full travel (100%)

6

Lens 1 move to rear EOT,

Lens 3 move to from EOT,

Lens 2 cycles full travel

(33%)

Table 4-3: VL6 Spot Luminaire Mechanical Tests (Continued)

Test Number

Test Parameter

Error Codes/Comments

Advertising