Series 300 luminaires, Connecting to system – PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 92

Advertising
background image

DMX512 R

EFERENCE

G

UIDE

8 4

02.3004.0300.54

Series 300 Luminaires

Refer also to

"DMX512 System Example" on page 7

.

Connecting to System

Series 300 luminaires require a Smart Repeater unit for power and control by DMX512 consoles.
Step 1. Position SixPack chassis delta/wye switches to correct setting.

Refer to

"Configuring Equipment For Delta or Wye Operation" on page 20

.

Step 2. Connect Modular Rack to power source.

Three-phase power will need to be supplied to the system. The maximum recommended
mod rack power requirement is 200 amps, using 2/0 feeder with 4/0 Cam-Lok connectors
and a 200A line disconnect. A SixPack Chassis requires 30 amps, and uses Hubbell or Epic
connectors on 8/5 multicore cable. Connector choice is dependent upon location. This cable
will need to be run from a house disconnect through a 30A line disconnect to the racks.

WARNING: The high voltages required to run this equipment are dangerous. Electrical "tie-ins"
should be handled by a qualified electrician.

Note: Some equipment in Europe will work using single-phase power. Check with an Account
Manager regarding your event.

To House
Disconnect

Tails

Series 200 AC Line

Disconnect

Modular Rack

Feeder Cable