2 6

02.3004.0300.54

Power and Data Distribution Equipment

AC Line Disconnect (200A)

CAUTION: Although the maximum operating limit is 200A, we recommend that continuous
operating current does not exceed 150A.

The 200A AC line disconnect is a safety device containing a
three-phase, 200A circuit breaker serving as a master on/off
switch for the system. The unit connects to house service
through a set of five, 10-foot, 2/0 pig tails. The line disconnect
connects to the ACS rack through a set of five, 20-foot and/or
80-foot, 2/0 pig tail cable assemblies. One line disconnect is
required for each 200A service.

Figure 2-1: AC Line Disconnect

OUTPUT

INPUT

Neutral (White)

X Phase (Black)

Y Phase (Red)

Z Phase (Blue)

Ground (Green)

Neutral (White)

X Phase (Black)

Y Phase (Red)

Z Phase (Blue)

Ground (Green)

Bare wire to Cam-Lok Pigtail cables

Cam-Lok to Cam-Lok

from House AC service

Pigtail cables to ACS or Mod Rack