Step 3. Configure APS6 modules. (There are two types of APS6 modules.)

a. For older APS6 modules, a blue programming jumper is used to configure the module in

either PSET or DCV mode and a jumper resistor assembly is used to configure the
module in either the 400W or 625W power output mode.

Note: Older style APS6 modules cannot be used with the VL6C/VL6C+, VL7, VL7U, VL7B, or
VL7UB luminaires, which require the 700W power output mode found on the new style modules.

Jumper settings:
400W PSET operation (normal fixed level wattage)
625W PSET operation (normal fixed level wattage)
400W DCV operation (0-10Vdc input required from SPC-36 controller)
625W DCV operation (0-10Vdc input required from SPC-36 controller)

1) At APS6 PCB header marked JMP2, carefully remove jumper from current setting.

Note: It is normal for jumper to hang one pin off the header in 400W DCV and 625W PSET modes.

2) Install jumper across required header pins.

400W PSET

625W PSET

625W DCV

400W DCV

Jumper Window

APS LVS

JMP 1

DCV PSET

JMP 2

625W Jumper Assembly