T

ESTING

AND

T

ROUBLESHOOTING

: T

EST

S

OFTWARE

0 2. 3 0 0 4. 0 3 00 . 5 4

111

4

1

Spin gobos CW (25%) wheel

does not move

0

Spin gobos CW (100%)

wheel does not move

010

Strobe Test

9

Strobe to EOT stop (65%)

(CLSD)

8

Strobe to middle position

between EOT Stop (66%)

(OPEN)

7

Strobe open to closed stop

repeatedly (25%) (i.e.

cycling)

6

Cycling (35%)

5

Cycling (45%)

4

Cycling (55%)

3

Cycling (65%)

2

Cycling (75%)

1

Cycling (85%)

0

Cycling (Full Speed)

013

All Async

All tests above will run asyn-

chronously. All motors will

reach respective EOT stop (if

applicable) and begin motion

to opposite EOT stops at

each motor’s earliest oppor-

tunity. Motion will not be coor-

dinated between motor.

Flashing display indi-

cates sensor not hit.

Solid display indicates

sensor hit.

021

Sensors

9

Monitor Lens 3 Sensor

8

Monitor Lens 2 Sensor

7

Monitor Lens 1 Sensor

6

Monitor Strobe Sensor

5

Monitor Fixed Gobo Sensor

4

Monitor Rotating Gobo

Wheel, Wheel position Sen-

sor and Gobo Orientation

Sensor

3

Monitor Plate 2 Saturation

Sensor

2

Monitor Plate 2 Color Sensor

1

Monitor Plate 1 Saturation

Sensor

0

Monitor Plate 1 Color Sensor

022/

023

Pan/Tilt Encoders

9

Display current most signifi-

cant digit (Xxxx) of the

reported encoder value.

Repeatedly monitored.

Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)