PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 120

Advertising
background image

DMX512 R

EFERENCE

G

UIDE

1 1 2

02.3004.0300.54

* Motors 1-8 actuate the framing blades and Motor 9 rotates the framing device.

8

Display current most signifi-

cant digit (Xxxx) of the

reported encoder value.

Repeatedly monitored.

7

Display current most signifi-

cant digit (Xxxx) of the

reported encoder value.

Repeatedly monitored.

6

Display current most signifi-

cant digit (Xxxx) of the

reported encoder value.

Repeatedly monitored.

0

Display scrolling snapshot of

each digit of the reported

encoder. Repeatedly moni-

tored.

024

Form and Function

0

Display the form and func-
tion value of the luminaire.

For the VL7 Py=F10 should

be reported where Y is the

luminaire’s port number.

071-
079*

Shutter System Motor

Test (Motors 1-9)

0

Full speed (100%) framing

from open stop to closed stop

repeatedly

Shutter Motor Tests

1

motor cycling (85%)

071

Operates Motor 1

2

motor cycling (75%)

072

Operates Motor 2

3

motor cycling (65%)

073

Operates Motor 3

4

motor cycling (55%)

074

Operates Motor 4

5

motor cycling (45%)

075

Operates Motor 5

6

motor cycling (35%)

076

Operates Motor 6

7

motor cycling (25%)

077

Operates Motor 7

8

End stop motor cycling (65%)

(OPEN)

078

Operates Motor 8

9

End stop motor cycling (65%)

(CLSD)

079

Operates Motor 9

Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)

Test Number

Test Parameter

Error Codes/Comments

Advertising